Black Twin Wall Flue (Insulated)


4 inch black twin wall insulated flue system4 inch black twin wall insulated flue system
5 inch black twin wall insulated flue system5 inch black twin wall insulated flue system
6 inch black twin wall insulated flue system6 inch black twin wall insulated flue system

Our range of twin wall flue products in black are completely interchangable with the stainless steel parts, as the only variation between the parts is the finish

 

About our Twin Wall

Our Twin wall system is manufactured by German suppliers Jeremias, and with over four decades of experience, rest assured that are you are recieving the best in heat insualted liners. The twin wall system is made from 304 outer and 316 inner stainless steel, with a thickness of 0.4-0.6mm and packed with rigid mineral wool insulation.

 

Installation

PLEASE NOTE THAT THE SIZE OF TWIN WALL ADVERTISED IS THE INTERNAL DIAMETER, AND THE EXTERNAL DIAMETER WILL BE 2 INCHES LARGER THAN THE INTERNAL

FOR EXAMPLE, A 1M OF 6" TWIN WALL HAS AN INTERNAL DIAMETER OF 6 INCHES, AND AN EXTERNAL DIAMETER OF 8" 

 

All of our Twin Wall products are the lengths specified, but as an installed length, you will lose 50mm on each part as it connects to another piece

Our twin wall is designed in mind to give you a hassle free installtion and with the push and fit mechanism, this allows for seamless integration of pieces in the same size bracket. 

Each piece of twin wall that is either a length, bend or adaptor is supplied with a locking band to connect it to another piece of your twin wall installtion to ensure that a safe connection is established between the parts.  

A minimum clearing distance of 60mm from any combustable materials must be maintained throughout the entirety of your installation.

When using the twin wall system, no more than four bends/offsets should be created as adding multiple/unnecessary bends can severely interfere with the heat flow.

When taking the twin wall through a roof, you must conform to the building regulation standards that state that the flue must be either 600mm above the ridge of the property or 2.3 meters horizontally from any weathered surface. 

 

General Notes 

You cannot attach the twin wall directly to the outlet of your appliacne as the insulation within the liner prevents a direct connection with your appliance, thus the use of an adaptor is essential.

If going through a wall, joints between pieces of black twin wall flue are ill advised unless no alternative can be made.