5" Register Plate Adaptor
It has a 5" connection on the underside of the plate to fit into your vitreous/stove pipe and above the 300mm x 300mm plate it has a 5" adaptor to connect directly to your flexible liner
5" Register Plate Adaptor
It has a 5" connection on the underside of the plate to fit into your vitreous/stove pipe and above the 300mm x 300mm plate it has a 5" adaptor to connect directly to your flexible liner
Construction | Stainless Steel |
---|---|
Inner Material: | 0.7mm Stainless Steel |
Fuels: | Gas, Oil, Logs, Peat and Smokeless Fuels |
Approvals | HETAS,CE,BSRIA, ISO9001 |
Installation Guide
Push the bottom end of ultraflex liner into the cavity between the inner and outer skin of the stainless steel adaptor, then drill through the outer skin, and secure with three self tapping screws,(not supplied).
now fill any gaps between the liner and outer skin of adaptor with fire cement,(note do not push fire cement inside the cavity before liner is inserted as will block the drainage holes)lastly push the bottom of the adaptor inside the flue pipe and seal with fire cement.
We recommend that all installations are carried out by a qualified chimney installer.
additional information on installation and requirements can be found below.
 Download Document J Regulations
Â
Â
Â